Shelf alarms menu, Shelf alarms menu -16, Figure 3-10.shelf alarms menu – ADC EMU-830 User Manual
Page 48

Chapter 3: Provisioning
3-16
Figure 3-9. LOS*, PFO* and LOSW* Alarm Reporting Screen
Shelf Alarms Menu
In the Config menu, press H to display the Shelf Alarms menu (
). This menu allows you to enable,
disable, and set the severity of the loss of shelf power, HDSL/G.SHDSL lines down, and loss of external clock alarm.
The Config menu also allows you to configure how each of the alarm relays respond to an ACO (Alarm Cut-Off). The
ACO can be activated from the EMU-830 front panel pushbutton or by connecting to ground the EXT (external) ACO
pin on the EMS-83x shelf's alarm connector. Selecting Enable (ENA) causes the associated alarm relay to be retired
(common contact connected to normally closed contact) when an ACO is received.
Figure 3-10. Shelf Alarms Menu
Note:
To select the Shelf Alarms menu for a different shelf, press ESC and then Q to return to the Network
screen, select a shelf with the
Ç
and
È
arrow keys, and press L to open the Main menu screen for that
shelf. Press C and then H to display the Shelf Alarms menu for the selected shelf.