Maintenance

heated. Install eyebolts (not supplied) into the lifting holes and use the pry slots to remove
intermediate cover (150).

NOTICE:
Allow the shaft and intermediate cover to cool to ambient temperature before proceeding
with disassembly.

13. Repeat steps 10 through 12 until all impellers, except 1st stage, and intermediate covers

are removed.

Model 7200CB, API Type BB5 Barrel Multistage / ISO 13709 2nd Edition / API 610 11th Edition Installation, Operation, and

77

Maintenance Manual