Goulds Pumps 7200CB - IOM User Manual
Page 18

Product Description
Nameplate field
Explanation
MAX. DES. WORKING
Maximum working pressure at temperature °C, in pounds per square inch
PRESS
S/N
Serial number of the pump
CONT./ITEM NO.
Customer contract or item number
IMP. DIA.
Rated impeller diameter
MAX. DIA.
Maximum impeller diameter
STD. DIM.
Standard ANSI dimensional code
MAT'L
Material of construction
Nameplate on the bearing frame
Table 1: Explanation of the nameplate on the bearing frame
Nameplate field
Explanation
BRG. O. B.
Outboard bearing designation
BRG. I. B.
Inboard bearing designation
S/N
Serial number of the pump
LUBE
Lubricant, oil or grease
ATEX nameplate
Nameplate field
Explanation
II
Group 2
2
Category 2
G/D
Pump can be used when gas and dust are present
T4
Temperature class
NOTICE:
Make sure that the code classifications on the pump are compatible with the specific
environment in which you plan to install the equipment. If they are not compatible, do not
operate the equipment and contact your ITT representative before you proceed.
16
Model 7200CB, API Type BB5 Barrel Multistage / ISO 13709 2nd Edition / API 610 11th Edition Installation, Operation, and
Maintenance Manual