Dismantling (pump with mechanical seals on shaft), Warning – Goulds Pumps 3408 - IOM User Manual
Page 46
DISMANTLING (PUMP WITH MECHANICAL SEALS ON SHAFT)
▲
!
WARNING
Prior to working on pump the power source
should be disconnected with lockout provisions
so power cannot be re-energized
to the motor. Close isolating suction and
discharge valves. Failure to follow these
instructions could result in properly damage,
sever personal injury, or death. (See exploded
view on page 64.)
1.
Drain the pump by opening vent plug (A, Fig. 28)
and remove drain plugs (B and C) on the suction
and discharge nozzles.
2.
Remove all casing main joint cap screws
(2-904-1) and dowels (2-916-1). Remove external
tubing (0-952-0).
3.
Insert a screwdriver or pry bar into the slots
between the upper and lower casing halves, and
separate the halves, lifting off the upper casing
half.
NOTE: Some casings have jacking screws.
42
3408 IOM 03/99
Fig. 27
Fig. 28
A- VENT PLUG
...........
è
B- DRAIN PLUG
......
è
C- DRAIN PLUG
..........
è
Dowel Pin Location
at Parting Line
- 3100 - IOM (52 pages)
- 3171 - IOM (60 pages)
- 3180-86 - IOM (158 pages)
- 3189 - IOM (32 pages)
- 3196 - IOM (148 pages)
- 3196 i-FRAME - IOM (152 pages)
- 3198 i-FRAME - IOM (126 pages)
- 3296 EZMAG - IOM (96 pages)
- 3296M - IOM (92 pages)
- 3298 - IOM (120 pages)
- 3311 - IOM (44 pages)
- 3316 - IOM (36 pages)
- 3335 - IOM (40 pages)
- 3355 - IOM (66 pages)
- 3393 - IOM (124 pages)
- 3408A - IOM (44 pages)
- 3409 - IOM (68 pages)
- 3410 - IOM (56 pages)
- 3420 - IOM (120 pages)
- 3498 - IOM (59 pages)
- 3500XD - IOM (44 pages)
- 3501 Mixer - IOM (48 pages)
- 3600 - IOM (110 pages)
- 3610 - IOM (98 pages)
- 3620 - IOM (98 pages)
- 3640 - IOM (98 pages)
- 3642 - IOM (12 pages)
- 3675 - IOM (12 pages)
- 3700 - IOM (110 pages)
- 3755 - IOM (32 pages)
- 3796 i-FRAME - IOM (134 pages)
- 3910 11th ed. - IOM (80 pages)
- 3935 - IOM (24 pages)
- 3996 - IOM (52 pages)
- 4550 - IOM (36 pages)
- 5000 - IOM (24 pages)
- 5100 - IOM (28 pages)
- 5150 - IOM (28 pages)
- 7200CB - IOM (132 pages)
- ANSI FAMILY IOM (ATEX Compliant) (56 pages)
- ANSI FAMILY IOM (ATEX Compliant) (27 pages)
- ANSI FAMILY IOM (ATEX Compliant) (42 pages)
- ANSI FAMILY IOM (ATEX Compliant) (45 pages)
- Pump Safety (9 pages)