beautypg.com

Installation, Receiving the pump, Lifting the pump – Goulds Pumps 3408 - IOM User Manual

Page 11

background image

INSTALLATION

RE CEIVING THE PUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
LIFTING THE PUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Hor i zon tal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Ver ti cal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

STOR AGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Tem po rary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Long Term . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

LO CA TION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
FOUN DA TION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
SETTING THE BASE PLATE . . . . . . . . . . . . . . . . . . . . . . . . . 14

Grouting Pro ce dure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

ALIGN MENT PRO CE DURE . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Method One. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Method Two. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

DOWELING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
SUC TION AND DIS CHARGE PIPING . . . . . . . . . . . . . . . . . . . . . 17

Suc tion Pip ing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Dis charge Pip ing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Pres sure Gauges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

STUFFING BOX LU BRI CA TION . . . . . . . . . . . . . . . . . . . . . . . 20

Packing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Me chan i cal Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Cartridge Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Cy clone Separators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

3408 IOM 03/99

11

RECEIVING THE PUMP

Check pump for shortages and damage immediately
upon arrival. (An absolute must!) Prompt reporting to
the carrier’s agent, with notations made on the freight
bill, will expedite satisfactory adjustment by the
carrier.

Pumps and drivers are normally shipped from the
factory mounted on a baseplate. Couplings may either

be completely assembled or have the coupling hubs
mounted on the shafts and the connecting members
removed. When the connecting members are
removed, they will be packaged in a separate
container and shipped with the pump or attached to
the baseplate.

LIFTING THE PUMP

The following instructions are for the safe lifting of
your pump.

The unit should be unloaded and handled by lifting
equally at four or more points on the baseplate. The
lugs on the upper half casing are designed for lifting
the upper half casing only.

HORIZONTAL

Bare Pump (Model 100)

1.

Using a nylon sling, chain, or wire rope, hitch
around both bearing housings. (See Fig. 3)