4.2.1

Diaphragm Removal & Reinstallation

1. Adjust the stroke setting to 50% and disconnect the power source to the drive motor.

2. Relieve all pressure from the piping system.

3. Close the inlet and outlet shutoff valves.

4. Place a pan underneath the pump head adaptor to catch any liquid leakage.

5. Disconnect piping to the reagent head and drain any process liquid, following all recommended

material safety precautions.

6. Remove all but one top reagent head bolt. Product will leak out between the pump head adaptor and

reagent head as the bolts are loosened. Use prescribed engineering controls to prevent exposure and
accidental discharge to environment.

7. Tilt the head and pour out any liquids retained by the check valves into a suitable container, continuing

to follow safety precautions as appropriate.

8. Remove the final bolt and rinse or clean the reagent head with an appropriate material.

9. Remove the diaphragm by turning it counter-clockwise.

10. Inspect the diaphragm. The diaphragm must be replaced if it is cracked, separated, or obviously

damaged.

11. Install the diaphragm.

a) Ensure that the critical sealing areas of diaphragm,

reagent head, and pump head are clean and free of
debris.

12. Thread the diaphragm (clockwise) fully onto the shaft.

13. Install the reagent head bolts and tighten in an

alternating pattern to ensure an even seating force.
Torque bolts to 4.5 N-M (40 IN-LBF).

14. Re-prime the pump following the procedure outlined in

Section 3.3

Figure 12: Reagent Head Assembly Cross Section