Spa Guidelines to Keep in Mind

Whether replacing an older control system, or if designing a new spa system,
keep these guidelines in mind.

The suction system for the 2-speed pump or for the circ pump must

1.

be dedicated. There must not be any other pumps connected to this
suction system.

The suction system for the 2-speed pump or for the circ pump must include

2.

the following:

a. 2 suction fittings, or

b. 1 suction fitting and a skimmer.

If the suction system for the 2-speed pump or for the circ pump includes

3.

a filter, it is desirable that the filter incorporate a by-pass around the
filter cartridge that opens when the cartridge gets dirty. (Spring tension
holding the by-pass valve closed must be overcome by the vacuum of the
pump.) This by-pass should be capable of flowing a minimum of 20 GPM
during the low speed operation of the 2-speed pump or during circ pump
operation with the cartridge 100% blocked. The inclusion of a suction fitting
appropriately plumbed into the suction circuit in conjunction with a vacuum
filter may also meet this requirement.

The pressure system for the 2-speed pump or for the circ pump must

4.

be dedicated. There must not be any other pumps connected to this
pressure system.