Revolution, Codes and compliance, Warning – Balboa Water Group Revolution User Manual
Page 84: Transforming the control of hot tubs, 230v ce, House breaker box gfci panel to spa & revolution

Revolution
Transforming the Control of Hot Tubs
84
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,
834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
Bond Lug
for
Spa Equipment
Main Electrical Connections
In BP1500 System
F3 10A 250V
F2 3A 250V
F6 0.3A 250V
J44
J24
J45
J15
W5
W4
J13
J16
J27
J25
J26
J23
J33
J28
J30
J31
J32
J29
J12
J46
J20
J57
J8
J14
J22
J21
J56
F5 30A
GND
K3
K5
K6
K2
K1
K4
K8
P2 / BL
PUMP 1
OZ
ONE
CIRC
22117_A
RED AC
GND
GND
WHT AC
HTR
A
HTR
B
J45
J46
J24
F4 1A 250V
J18
J19
K7
T1
J15
J33
S1
S6
J31 HCE
J30 TST
J27
H3
J22
J26 H2
J25 H1
J17
J16
J29 VAC
J28 AUX FRZ
J5
LIGHT
ON
22112_A
L2
GND
L1
N
50
LOAD 1
BLACK
LOAD 2
RED
LOAD
NEUTRAL
LINE
NEUTRAL
LINE 2
RED
LINE 1
BLACK
120 V
A
C
120 V
A
C
Neutral
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
House
Breaker Box
GFCI
Panel
To Spa &
Revolution
Codes and Compliance
All of the electrical wiring methods and materials used to complete the
t
electrical installation of the Revolution control system must be
in accordance with the National Electrical Code or the Canadian
Electric Code, as well as any local electrical codes in effect at the
time of installation.
The selection of electrical materials required to accomplish this installation
t
and the installation of the control system must be made by, or be under
the direct supervision of, a qualified electrician.
The Revolution is classified as a “
t
continuous duty appliance” and
is intended primarily for installation at a single family dwelling. The
installation recommendations and instructions contained in this manual are
directed solely toward these issues.
WARNING!
If there is any doubt whether the system that you are installing into does not
have these features, contact a licensed, qualified electrician. Do not attempt
to modify the wiring yourself.
240V Domestic
L2
L1
N
F3 10A 250V
F2 3A 250V
J44
J48
J1
J2
J24
J45
J49
J15
J16
J47
J13
J27
J25
J26
J23
J33
J28
J30
J31
J32
J29
J12
J46
J20
J57
J8
J14
J22
J21
J56
GND
K3
K5
K6
K2
K1
K4
OZ
ONE
22117_B
RED AC
GND
GND
WHT AC
HTR A
HTR B
UNFUSED
T 150 m A
250V
F5 T 30A
CIRC
1S PUMP 1
1S PUMP 2
GRN
N
L1
N/A
ADDED JUMPER FOR
CE INSTALLATIONS
BLU
BRN
230V CE