beautypg.com

Revolution, It electrical system (no neutral), Transforming the control of hot tubs – Balboa Water Group Revolution User Manual

Page 69

background image

Revolution

Transforming the Control of Hot Tubs

69

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,

834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

IT Electrical System (No Neutral)

TN and TT Electrical Services (Line, Neutral, Ground), IT Power Requirements

Single Service [3 wires (line, line, ground)]

230VAC, 50Hz, 1þ, 16A/32A, (Circuit Breaker rating = 20A/40A max.)

Protective Earth Wire (Green/Yellow) must be connected to system ground

t

terminal as marked.

All equipment (pumps, blower, and heater) runs on service line L1 with L2

t

acting as the return - 230VAC.

Set the DIP switches according to the wiring diagram so that total system

t

current draw never exceeds the rated service input when using a particular
setup.

Three Service [4 wires (line, line, line, ground)]

230VAC, 50Hz, 1þ, 16A/32A, (Circuit Breaker rating = 20A/40A max.)

Protective Earth Wire (Green/Yellow) must be connected to system ground

t

terminal as marked.

All equipment (pumps, blower, and heater) runs on service line L1 with L2

t

acting as the return - 230VAC.

Set the DIP switches according to the wiring diagram so that total system

t

current draw never exceeds the rated service input when using a particular
setup.

L2

L1

N

GRN

L2

L1

L3

N/A

BRN

BRN

LINE 3 - CAP (INSULATE) END.

DO NOT CONNECT.

BRN

L2

L1

N

GRN

L2

L1

N/A

BRN

BRN