Cycle time adjustments, Softener setup, Type – Hellenbrand H-125 Series User Manual

Page 9: Manual regeneration, Regeneration mode

background image

9

Manual regeneration

Sometimes there is a need to regenerate the system, sooner than when the system calls for

it, usually referred to as manual regeneration. There may be a period of heavy water usage

because of guests or a heavy laundry day.

To initiate a manual regeneration at the preset delayed regeneration time, press and

release “REGEN”. The words “REGEN TODAY” will flash in left corner of display as it

scrolls through displays to indicate that the system will regenerate at the preset delayed

regeneration time. If you pressed the “REGEN” button in error, pressing the button

again will cancel the request.

To initiate a manual regeneration immediately, press and hold the “REGEN” button for five seconds. The system will begin to regen-

erate immediately. The request cannot be cancelled. You must cycle all the way through the cycles to make it stop. PLEASE NOTE:

This will reset the meter.

Note: If the salt tank does not contain salt, fill with salt and wait at least two hours before regenerating. If two regenerations

are desired within 24 hour period, press /release REGEN button. REGEN TODAY will flash on screen. Press and hold REGEN

button until valve initiates regeneration.

Figure 11

CYCle TiMe aDJusTMenTs

Normally it is not recommended to adjust the lengths of the cycle times. However, certain water conditions may

dictate adjustments. This should only be done from the recommendation of a water conditioning professional.

The following chart shows the upper and lower limits of each cycle.

Cycle Options

Units

Lower/Upper Limit Factory Setting

Fill

Lbs.

0.1 to 200

See Page 33

Softening (Service)

Minutes

1 to 480

120

Backwash

Minutes

1 to 120

8

Regenerant Draw DN

Minutes

1 to 180

60

Backwash

Minutes

1 to 120

8

Rinse-Fast

Minutes

1 to 120

4

Step 1S

Step 2S

SOFTENING

Step 3S

FILL

20.0

STEP 1S – Press NEXT and  simultaneously for 3 seconds. If screen in Step 2S does

not appear in 5 seconds the lock on the valve is activated.

STEP 2S – Select between softening or filtering. A flashing "SOFTENING" or "FIL-

TERING" will appear. Choose SOFTENING using  or  button. Factory setting is

Softening. Press NEXT to go to Step 3S. Press REGEN to exit Softener System Setup.

STEP 3S – Select the time for the first cycle (which in this example is FILL, setting is

changed by lbs. of salt entered) using the  or  button. Factory setting is Medium

Salting, See page 33. Press NEXT to go to Step 4S. Press REGEN to return to previous

step.

"REGEN TODAY"

320

CAPACITY REMAINING

GAL

sOfTener seTup

Regeneration Step

(shows time remaining in regen step

is 8 minutes, 22 seconds)

BACKWASH

8:22

=  Up Arrow =  Down Arrow

SET

SET

TYPE

LBS

Regeneration Mode

Typically a system is set to regenerate at a time of low water usage. An example of a time with

low water usage is when the household is asleep. If there is a demand for water when the system

is regenerating, untreated water will be supplied.

When the system begins to regenerate, the display will change to include information about the

step of the regeneration process and the time remaining for that step to be completed (see figure

11). The system runs through the steps automatically and will reset itself to provide treated water

when the regeneration has been completed.