Water meter and meter plug bypass valve – Hellenbrand H-125 Series User Manual
Page 27
27
Not Shown 15-V3191-01
Bypass 90º Vert. Assy.
1
15-V3151
Nut 1” Quick Connect
2
2
15-V3150
Split Ring
2
3
15-V3105
O-Ring 215
2
Not Shown 15-V3191-01
Bypass Vertical Adpt.Assy (set of 2) 1
WaTer MeTer anD MeTer pluG
bYpass valve
1
15-V3151
Nut 1” QC
1
2-4
15-V3003*
Meter Assy.
1
3
15-V3118-01
Turbine Assy.
1
4
15-V3105
O-ring 215
1
5
15-V3003-01
Meter Plug Assy.**
1
QTY.
ITEM NO. ORDER NO.
DESCRIPTION
*Order number 15-V3003 includes 15-V3118-01 and 15-V3103, which are
item numbers 3 & 4.
**Only used if metering is not to be done (time clock units)
The nuts and caps are designed to be unscrewed or tightened by hand or
with the special plastic wrench. If necessary a pliers can be used to un-
screw the nut or cap. Do not use a pipe wrench to tighten or loosen nuts or
caps. Do not place screwdriver in slots on caps and/or tap with a hammer.
The nuts and caps are designed to be unscrewed or tightened by hand or
with the special plastic wrench. If necessary a pliers can be used to un-
screw the nut or cap. Do not use a pipe wrench to tighten or loosen nuts or
caps. Do not place screwdriver in slots on caps and/or tap with a hammer.
Do not use pipe dope or other sealants on threads. Teflon tape must be
used on threads of the 1” NPT connection and on the threads for the drain
line connection. Teflon tape is not necessary on the nut connection nor
caps because of o-ring seals.
Figure 20
Figure 21
QTY.
ITEM NO. ORDER NO.
DESCRIPTION