Valve history – Hellenbrand H-125 Series User Manual
Page 14
14
STEP 1VH – Press and simultaneously for three seconds and release, then
press and simultaneously and release. If screen in step 2VH does not appear
in 5 seconds the lock on the valve is activated.
STEP 2VH – Days, total since start-up: This display shows the total days since
startup. Press the NEXT button to go to Step 3VH. Press REGEN to return to
previous step.
STEP 3VH – Regenerations, total number since start-up: This display shows the
total number of regenerations that have occurred since startup. Press the NEXT
button to go to Step 4VH. Press REGEN to return to previous step.
STEP 4 VH – Volume, total used since start-up: This display shows the total
gallons treated since startup. This display will equal zero if a water meter is not
installed. Press NEXT button to exit Valve History. Press REGEN to return to
previous step.
Use and arrows to display sequential error codes.
Step 1VH
valve hisTOrY
Step 2VH
970
TOTAL DAYS
Step 3VH
235
Step 4VH
175
GAL
x1K
(Can not be reset)
TOTAL REGENS
TOTAL GALLONS
RETURN TO ROTATING DISPLAY
1- - -
ERROR LOG