General specifications programming options – Hellenbrand H-125 Series User Manual

Page 34

background image

34

OPERATING PRESSURES

Minimum/Maximum ..................................................................................................................................25 psi-125 psi

OPERATING TEMPERATURES

Minimum/Maximum ..................................................................................................................................40º - 110º F

METER

Accuracy ...................................................................................................................................................±5%

Flow Rate Range......................................................................................................................................0.25 - 34 GPM

Gallon Range ...........................................................................................................................................20 - 50,000

DIMENSIONS

Drain Line .................................................................................................................................................3/4” or 1” NPT

Brine Line .................................................................................................................................................3/8” Poly Tube

Electrical Current Draw and Voltage ........................................................................................................0.5A 110v

Compatible with the following regenerants or chemicals: Sodium chloride, potassium permanganate, sodium bisulfite, sodium hydroxide,
hydroxide, hydrochloric acid, chlorine and chloramines.

General speCifiCaTiOns

prOGraMMinG OpTiOns

AUTO

DELAY

oFF

Reserve capacity automatically estimated.

Regeneration occurs when gallons capacity falls below the reserve capacity at the next

Regen Set Time.

AUTO

DELAY

1 to 28

Reserve capacity automatically estimated.

Regeneration occurs at the next Regen Set Time when gallons capacity falls below the

reserve capacity or the specified number of days between regenerations is reached.

DELAY

oFF

Reserve capacity not automatically estimated.

Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0.

DELAY

oFF

Reserve capacity not automatically estimated.

Regeneration occurs at the next Regen Set Time when the specified number of days

between regenerations is reached.

DELAY

Reserve capacity not automatically estimated.

Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0 or the

specified number of days between regenerations is reached.

AUTO

IMMEDIATE

oFF

Reserve capacity not automatically estimated.

Regeneration occurs immediately when gallons capacity reaches 0.

Time of regeneration will not be allowed to be set because of regeneration will always

occur when gallons capacity reaches 0.

DELAY + IMMEDIATE

oFF

Reserve capacity not automatically estimated.

Regeneration occurs immediately when gallons capacity reaches 0.

Time of regeneration will not be allowed to be set because regeneration will always

occur on 0.

AUTO

oFF

Reserve capacity automatically estimated.

Regeneration occurs when gallons capacity falls below the reserve

capacity at the next Regen Set Time or regeneration occurs immediately after

10 minutes of no water usage when gallon capacity reaches 0.

AUTO*

Reserve capacity automatically estimated.

Regeneration occurs at the next Regen Set Time when gallons capacity

falls below the reserve capacity or the specified number of days between regenerations

is reached or regeneration occurs immediately after 10

minutes of no water usage when gallon capacity reaches 0.

Reserve capacity not automatically estimated.

Regeneration occurs at the next Regen Set Time when specified number of days be-

tween regenerations is reached or regeneration occurs immediately after 10 minutes

of no water usage when gallon capacity reaches 0.

1 to 28

1 to 28

1 to 28

1 to 28

*14

20 to

250,000

20 to

250,000

20 to

250,000

20 to

250,000

Reserve

Gallons

Regeneration

Type

Days

Override

Results

(Reserve capacity estimate based on history of water usage)

*Factory settings in bold

To "lockout" access to modification settings, diagnostic and valve history displays except hardness, day override and time,

press

X

next,

X

and clock in sequence to "unlock" press

X

next,

z

and clock in sequence.

DELAY + IMMEDIATE

DELAY + IMMEDIATE

DELAY + IMMEDIATE