Appendix D. S-Register List

61202.029L2-1

ISU 128 User Manual

111

S42

BOND TXADD01

The number of seconds both endpoints wait for the

additional call to be connected at the end of negotiation

before deciding the BONDING call has failed. When

dialing overseas, it may be necessary to lengthen this

timer to allow for lower call routing.

Range = 0 to 255, 50 sec is default

S43

BOND TXDEQ

The number of seconds both endpoints attempt to

equalize the network delay between the bearer channels

before deciding the BONDING call has failed.

Range = 0 to 255, 50 sec is default

S44

BOND TANULL

The number of seconds the answering endpoint attempts

to detect the BONDING negotiation pattern from the

originating endpoint before aborting to clear channel

mode. It may be necessary to shorten this timer if the

DTE equipment connected to the ISU 128 also has

timer constraints for completing non-BONDING para-

meter negotiation.

Range = 0 to 255, 10 sec is default

S45

BOND TCID

The number of seconds both endpoints attempt to

negotiate agreeable values for bearer channels and

channel capacities before deciding the BONDING

call has failed.

Range = 0 to 255, 5 sec is default

S46

V25 MODE

Selects the type of V.25 bis dialing used.

0 = Asynchronous V.25

1 = HDLC V.25

2 = BISYNC V.25

3 = HDLC with flags V.25

S47

RS-366 TIME

Determines the amount of time the RS-366 port will wait

for EON or inactivity to terminate a dial string before

dialing a number.

0 = Wait for EON only

10= Wait for 1 second or EON

20= Wait for 2 seconds or EON

50= Wait for 5 seconds or EON

100=Wait for 10 seconds or EON

200=Wait for 20 seconds or EON

S50

LINE MODE

Selects the operating mode of the ISU 128.

0 = Dial service (switched service)

1 = Leased service (non-switched service)