Setting local events

To set the events:

1

In the navigation pane, select Event Log under the Monitors heading.

The Monitored Local Events window appears (see

Figure 15, Monitored local events,

on page

38).

Figure 15: Monitored local events

See

Table 6, Monitored local events,

on page 38 for an explanation of monitored local alerts.

Table 6: Monitored local events 1 of 2

Event

Action

Event log 75% full

[default: Enabled]: Generates an event if the event log reached 75% of
capacity.

Event log full

[default: Enabled]: Generates an event if the event log reaches capacity.
When the event log reaches capacity, the oldest entries in the log are
deleted by new entries.

Redundant power supply
failure

Not used on the S8500 Media Server configuration.

Voltage irregularity

[default: Enabled]: Generates an event if the monitored voltages exceed
their thresholds.

Power off

[default: Enabled]: Generates an event if the power to the S8500 Media
Server is turned off.

1 of 2