beautypg.com

Setting asm date and time – Avaya S8500 User Manual

Page 27

background image

Using the Avaya Remote Supervisor Adapter

ASM control

Avaya Remote Supervisor Adapter User Guide

27

November 2003

6

NMI Reset Delay [default: Disabled]: Use this field to specify the time in minutes that the RSA
waits to restart the S8500 Media Server after a nonmaskable interrupt (NMI) generates. A NMI
can be triggered by:

A critical error such as a hardware fault.

A parity error in the memory subsystem.

To set the NMI Reset Delay, select a value from the drop-down menu. To turn this option off,
select Disabled.

7

Scroll to the bottom of the page and slick Save.

Setting ASM date and time

Alerts that are sent from the RSA are time stamped using the RSA internal clock. The RSA internal clock
uses Greenwich Mean Time (GMT) and Daylight Saving Time (DST) to enable administrators to manage
servers that reside in different time zones.

To set the date and time:

1

In the navigation pane, select System Settings under the ASM Control heading.

The ASM Date and Time window appears (see

Figure 5, ASM date and time,

on page 27).

Figure 5: ASM date and time

2

Scroll down to the ASM Date and Time section and click Set ASM Date and Time.

The ASM Date and Time window opens (see

Figure 6, ASM Date and Time,

on page 27).