Faults with display – Karcher B 150 R Bp Dose User Manual
Page 25

-
10
Faults with display
Display
Cause
Remedy
Seat switch open!
Seat contact switch has not been
activated.
Release the drive pedal. Have a seat.
Release accelerator! The gas pedal is depressed when
the main switch is on.
Release drive pedal and reactivate.
No direction of travel! Travel direction switch or cable
connection defective.
Call customer service.
Battery discharged!
Battery voltage too low.
Charge battery.
Battery voltage inad-
missible!
Battery voltage is above or below
the admissible range.
Call customer service.
Charger defective!
Error on the charger, charging is
not possible.
Check the charger.
Fresh water tank
empty!
The fresh water tank is empty.
Fill up fresh water reservoir.
Brush pressure not
reached!
Timeout brush contact pressure
control.
Check brush wear, replace brush if required.
Check the function of the brush heads: lowering, raising.
Waste water tank
full!
wastewater reservoir is full.
Empty the dirt water reservoir.
Level sensor or cable connection
defective.
Call customer service.
Brake defective!
Brake defective.
Do not drive the appliance.
Call customer service.
Propulsion motor
hot! Allow to cool
down!
Motor protection was triggered
Bring the safety switch into the "0" position.
Allow machine to cool down at least for 15 minutes.
Contact aftersales service in case of recurrence.
Horn defective!
Horn defective.
Call customer service.
Control is hot! Allow
to cool down!
Performance electronics of lift
module (A4) too hot
Bring the safety switch into the "0" position.
Allow control to cool down at least 5 minutes.
Significantly reduce the brush pressure with rough ground.
Contact aftersales service in case of recurrence.
Brush motors over-
loaded!
Load of the brush heads asym-
metric.
Adjust brush level.
25