Filling system (optional), Metering system (only dose model), Setting the parameters – Karcher B 150 R Bp Dose User Manual
Page 21: With yellow intelligent key, Setting the vacuum bar, Oblique position, Inclination, Adjust wiping flaps, Spray nozzle (option), Emptying the dirt water reservoir
-
6
Connect the water hose to the connec-
tion neck on the filling system.
Open the water supply.
Once the maximum fill level is reached,
the built-in floater valve will stop the wa-
ter inflow.
Shut off water supply.
Remove the water hose.
Detergent is added to the fresh water on
the way to the cleaning head with the help
of a dosaging device.
Place the detergent bottle into the de-
vice.
Close the bottle lid.
Insert the suction hose of the dosaging
equipment into the bottle.
Note:
The dosing unit can be used to add 3% de-
tergent at maximum. With higher dosage
the detergent must be put into the fresh wa-
ter tank.
ATTENTION
Risk of clogging due to dried detergent
when the detergent is added to the fresh
water tank of the Dose version. The flow
meter of the dosing equipment can aggluti-
nate on account of drying detergent and
hamper the functioning of the dosing equip-
ment. Subsequently rinse the fresh water
tank and the appliance with clear water. For
rinsing, select cleaning programme with
application of water at the programme se-
lector switch. Set the water quantity to the
highest value, set the detergent dosage to
0%
Note:
The appliance is equipped with a fresh wa-
ter indicator in the display. If the fresh water
tank is empty, the function of adding deter-
gent gets deactivated. The cleaning head
continues to work without liquid supply.
Parameters for the different cleaning pro-
grammes are preset in the appliance.
Depending on the authorisation of the yel-
low Intelligent Key, individual parameters
can be changed.
The modification of the parameters is only
valid until another cleaning programme is
selected via the programme selection
switch.
If you wish to permanently change the pa-
rameters, you must use a grey Intelligent
Key. This adjustment procedure is de-
scribed in the section "Grey Intelligent
Key“.
Note:
Almost all displayed text regarding param-
eter adjustment is self-explanatory. The
only exception is the parameter FACT:
–
Fine Clean: Lower brush speed for re-
moving the grey film on fine stone
floors.
–
Whisper Clean: Medium brush speed
for regular cleaning with reduced noise
level.
–
Power Clean: High brush speed for pol-
ishing, crystallising and sweeping.
Turn the program selection switch to
the desired cleaning program.
Turn the info button until the desired pa-
rameter is displayed.
Press Info button - the set value blinks.
Set the desired value by turning the info
button.
Confirm the changed setting by press-
ing the Info button or wait till the set val-
ue is automatically accepted after 10
seconds.
To improve the vacuuming result on tiled
floors the vacuum bar can be turned to an
oblique position of up to 5°.
Release the wing nuts.
Turn the vacuum bar.
Tighten the wing nuts.
If the vacuum result is unsatisfactory the in-
clination of the straight vacuum bar can be
modified.
Adjust the rotary handle to incline the
suction bar.
Adjust the wiper flaps by turning the ad-
justment wheel so that they touch the
floor.
Turn the adjustment wheel an addition-
al turn toward the bottom.
The hose with the spray nozzle is attached
to the back of the appliance. It serves for
washing away dirt and for manual cleaning
of the wastewater tank.
Turn programme selector switch to
"transport run".
Press Info button.
Turn the info button until "tank rinsing"
is shown on the display.
Press Info button.
Turn the info button until "ON" is dis-
played.
Press Info button.
The water pump delivers fresh water
through the spray nozzle.
Note:
Overflow waste water tank. When the
wastewater tank is full, the suction turbine
switches off and "Waste water tank full" is
shown on the display.
ṇ
WARNING
Please observe the local provisions regard-
ing the wastewater treatment.
Take the dirt water discharge hose from
the support and lower above a suited
collection device.
Note:
The wastewater flow can be controlled by
squeezing the dosing unit.
Let off water by opening the dosage de-
vice at the discharge hose.
The rinse the dirt water reservoir with
clear water.
Open the lock of the fresh water reser-
voir.
Drain the fresh water.
Attach the closure of the fresh water
tank.
Check the waste container. If needed,
remove and empty waste container af-
ter work.
Remove the Intelligent Key.
Secure the machine with wheel chocks
to prevent it from rolling away.
Charge battery, if required.
Plug in the Intelligent Key.
Select the desired function by turning
the Info button.
The different functions are described in the
following.
Turn programme selector switch to
"transport run".
Press Info button.
In the transport run menu the following set-
tings can be made:
Filling system (optional)
Metering system (only Dose model)
Setting the parameters
With yellow Intelligent Key
Setting the Vacuum Bar
Oblique position
Inclination
Adjust wiping flaps
Spray nozzle (option)
Emptying the Dirt Water Reservoir
Emptying the Fresh Water Tank
Empty waste container (only with R
cleaning head)
Shutting down
Grey Intelligent Key
Transport run
21