beautypg.com

Key management, Selecting the brush shape, Stopping times – Karcher B 150 R Bp Dose User Manual

Page 22: Setting the battery type, Standard setting, Setting the language, Factory setting, Cleaning programs, Transport, With mounted d cleaning head

background image

-

7

In this menu item the authorisations for yel-
low intelligent keys as well as the
language of the display texts are selected.

Turn the info button until "key man-
agem." is shown on the display.

Press Info button.

Remove the grey Intelligent Key and in-
sert the yellow Intelligent Key to be pro-
grammed.

Select the desired menu item to be
modified by turning the Info button.

Press Info button.

Adjust the menu item by turning the Info
button.

Confirm the setting by pressing the
menu item.

Select the next menu item to be modi-
fied by turning the Info button.

In order to save the authorisations, call
the "Save?" menu by turning the info
button and then press the info button.

"Continue key menu":
Yes: Programme further Intelligent Key.
No: Exit key menu.

Press Info button.

This function is required when changing the
cleaning head.

Turn the info button until "brush head" is
shown on the display.

Press Info button.

Turn the info button until the desired
brush shape is highlighted.

Press Info button.

Move the hoist drive for replacement of
the cleaning head by turning the info
button:
up: Raise
down: Lower
OFF: Stop

Exit menu: Select "OFF" by turning the
info button and press the info button.

When exiting the menu, the control per-
forms a restart.

Turn the info button until "stopping
times" is shown on the display.

Press Info button.

Turn the info button until the desired as-
sembly is highlighted.

Press Info button.

Turn the info button until the desired
stopping time is reached.

Press Info button.

Turn the info button until "Battery menu"
is displayed.

Press Info button.

Turn the info button until the desired
battery type is highlighted.

Press Info button.

Changes of the parameters of the individu-
al cleaning programmes that were made
during the operation are reset to the basic
setting after switching off the appliance.

Turn the info button until "Basic setting"
is displayed.

Press Info button.

Turn the info button until the desired
cleaning programme is displayed.

Press Info button.

Turn the info button until the desired pa-
rameter is displayed.

Press Info button - the set value blinks.

Set the desired value by turning the info
button.

Press Info button.

Turn the info button until "Language" is
displayed.

Press Info button.

Turn the info button until the desired
language is highlighted.

Press Info button.

The factory settings of all parameters are
restored.

Parameters that are adjusted with the grey
Intelligent Key, are kept until another set-
ting is selected.

Turn the program selection switch to
the desired cleaning program.

Press the info button - the first adjusta-
ble parameter is displayed.

Press Info button - the set value blinks.

Set the desired value by turning the info
button.

Confirm the changed setting by press-
ing the Info button or wait till the set val-
ue is automatically accepted after 10
seconds.

Select the next parameter by turning
the Info button.

After all desired parameters have been
modified, turn the info button until "Exit
menu" is displayed.

Press the info button - you will exit the
menu.

ƽ

DANGER

Risk of injury! When loading or unloading
the machine, it may only be operated on
gradients of max. 10%. Drive slowly.

CAUTION

Risk of injury and damage! Observe the
weight of the appliance when you transport
it.

When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.

Remove brushes from the brush head.

CAUTION

Risk of injury and damage! Note the weight
of the appliance in case of storage.

This appliance must only be stored in
interior rooms.

Select the storage site for the appliance
taking into consideration the permissi-
ble total weight of the appliance in order
not to impact its stability.

ƽ

DANGER

Risk of injury! Before working on the appli-
ance, remove the Intelligent Key and the
mains plug of the charger.
Pull out the battery plug.

Drain and dispose of the dirt water and
the residual fresh water.

CAUTION

Risk of injury due to overrun of the suction
turbine.
Suction turbine will continue to run for a
while after switch-off. Carry out mainte-
nance tasks only after the suction turbine
has come to a halt.

ATTENTION
Risk of damage. Do not sluice the appli-
ance with water and do not use aggressive
detergents.

Drain off dirt water.

Clean protective turbine strainer.

Only with R cleaning head Remove bulk
waste container and empty it.

Clean the outside of the appliance with
a damp cloth which has been soaked in
mild detergent.

Clean the vacuum lips and the wiping
lips, check for wear and replace if re-
quired.

Check the brushes for wear, replace if
required.

Charge battery.

During long operating pauses: Carry
out refill charging for the battery.

Check battery poles for oxidation, brush
off if necessary. Ensure firm seating of
the connection cable.

Clean the seals between dirt water res-
ervoir and cover and check for tight-
ness, replace if required.

Check the acid density of the cells if the
batteries are not maintenance-free bat-
teries.

Clean the brush tunnel (only R cleaning
head)

Remove the water distribution strip from
the cleaning head and clean water ca-
nal (only R cleaning head).

Have the prescribed inspection carried
out by the customer service.

Key management

Selecting the brush shape

Stopping times

Setting the battery type

Standard setting

Setting the language

Factory setting

Cleaning Programs

Transport

With mounted D cleaning head

Storage

Maintenance and care

Maintenance schedule

After the work

Monthly

Yearly

22

EN

This manual is related to the following products: