beautypg.com

Operator console, Programme switch, Symbols on the machine – Karcher B 150 R Bp Dose User Manual

Page 18: Before startup, Batteries, Recommended batteries, Insert batteries and connect

background image

-

3

1 Safety button
2 Programme switch
3 Intelligent Key
4 Info button
5 Display
6 Drive direction switch
7 Horn

1 OFF

Device is switched off

2 Transport run

Driving to the Place of Use.

3 Eco programme

Wet clean the floor (with reduced brush
speed) and vacuum up wastewater
(with reduced suction).

4 Scrubbing suction

Wet clean the floor and vacuum up dirt
water.

5 Heavy programme

Wet clean the floor (with increased
brush contact pressure) and vacuum up
dirt water.

6 Scrubbing

Wet clean the floor and allow the deter-
gent to react.

7 Vacuuming

Suck in the dirt fleet.

8 Polishing

Polishing the floor without the applica-
tion of liquid.

** option

ƽ

DANGER

Risk of explosion!
Do not place tools or similar items on the
battery. Risk of short-circuit and explosion.
Risk of injury. Ensure that wounds never
come into contact with lead. Always clean
your hands after having worked with batter-
ies.

The "Pack" model contains built-in batter-
ies.

Bring the safety switch into the "0" posi-
tion.

Tilt the wastewater tank backwards.

4.035-987.7

4.035-988.7

Operator console

Programme switch

Symbols on the machine

Handle for swivelling up the
waste water tank

Lashing point

Mop holder **

Water connection filling sys-
tem **

Water connection for waste-
water tank rinsing system **

Drain outlet fresh water tank

Drain outlet waste water tank

Before Startup

Batteries

Observe the directions on the bat-
tery, in the instructions for use
and in the vehicle operating in-
structions
Wear eye protection

Keep children away from acid and
batteries

Danger of explosion

Fire, sparks, naked flames and
smoking must be strictly avoided

Danger of chemical burns

First aid

Warning note

Disposal

Do not throw the battery into the
regular waste

Recommended batteries

Order No.

Volume [m

3

} *

Air flow [m

3

/h] **

Battery set
240Ah, trough,
low-mainte-
nance

4.035-
987.7

27

10,8

Battery set
180Ah, trough,
low-mainte-
nance

4.035-
988.7

20,25 8,1

Battery set
240Ah, 6
blocks, mainte-
nance-free

4.654-
306.7

6,975 2,79

Battery set
180Ah, 6
blocks, mainte-
nance-free

4.654-
307.7

5,175 2,07

* Minimum volume of the battery charg-
ing room
** Minimum air flow between the battery
charging room and the surroundings

Insert batteries and connect

18

EN

This manual is related to the following products: