background image

– 4

Release the star grips of the pushing
handle fastening.

Turn the pushing handle backwards
and tighten the star grips.

Place long lateral boards of the packag-

ing as a ramp next to the pallet.

Fix the ramp on the pallet with nails.

Place short boards as a support under-

neath the ramp.

Remove the wooden bars in front of the

wheels.

Push down the appliance through the

ramp from the pallet.

The brushes must be installed before the
initial operation (see "Maintenance works").

Insert the vacuum bar into the vacuum

bar suspension in such a manner that

the profiled sheet is positioned above

the suspension. Tighten the wing nuts.

Insert the suction hose.

Warning!

Risk of damage. Raise the vacuum bar be-
fore reversing.
Note
To put the brush drive out of operation im-
mediately release the control handle.

Warning

Risk of damage. Only use the recommend-
ed detergents. With respect to different de-
tergents the operator bears the increased
risk regarding the operational safety and
danger of accident. Only use detergents
that are free from solvents, hydrochloric
acid and hydrofluoric acid.
Note
Do not use highly foaming detergents. Ob-
serve the dosing notes.

Recommended detergents:

Open the cover of the fresh water reser-
voir.

Before Startup

Unloading

Installing the Brushes

Installing the Vacuum Bar

Operation

Filling in Detergents

Application

Detergent

Routine cleaning of all wa-
ter resistant floors

RM 745 RM
746

Routine cleaning of glossy
surfaces (e.g. granite)

RM 755 es

Routine cleaning and basic
cleaning of industrial floors

RM 69

Routine cleaning and basic
cleaning of fine stoneware
tiles

RM 753

Routine cleaning of tiles in
sanitary areas

RM 751

Cleaning and desinfection
in sanitary areas

RM 732

Removal of coating from all
alkali-resistant floors (e.g.
PVC)

RM 752

Removal of coating from li-
noleum floors

RM 754

17

EN