9.2

Errors During Welding

All errors that occur while welding is in progress are also indicated by an audible alarm.

Low Voltage

The input voltage is below 175 volts. If the error condition persists for longer than 15 seconds,

the welding process will be aborted. If the voltage goes down below 170 volts, the welding

process will abort immediately.

Overvoltage

The input voltage is over 290 volts. If the error condition persists for longer than 15 seconds, the

welding process will be aborted.

Resistance Error

The resistance value of the connected fitting is out of the read tolerance.

Frequency Error

The frequency of the input voltage is out of tolerance (42 Hz - 69 Hz).

Voltage Error

Check generator voltage and current. The output voltage does not correspond to the value

previously read; the welding unit has to be sent to the manufacturer for check-up.

Low Current

The message is displayed if the there is a momentary current failure or if the current decreases by

more than 15% per second for 3 seconds.

Excess Current

The output current value is in excess; possible causes: short-circuit in the heater coil or the

welding cable. During the start stage the upper abort threshold equals 1.18 times the value at

start, in any other case the upper limit depends on the load value and is calculated as the current

at start plus 15%.

Emergency Off

The welding process has been interrupted by pressing the STOP/RESET key.

Heater Coil Error

The dynamic current value during welding differs by more than 15% from the required value,

indicating a short-circuit in the heater coil.

Power Supply Failure at Last Welding

The last welding is incomplete. The welding unit was disconnected from the power supply voltage

while it was in progress. To go on using the unit, this error has to be acknowledged by pressing

the STOP/RESET key (see also Sect. 7.4).

10 Technical Data

Operating Range .................................... ≤ Ø 1200 mm

Nominal Voltage .................................... 230 V

Frequency .............................................. 50 Hz / 60 Hz

Power .................................................... 2800 VA, 80% duty cy

Protection Index ..................................... IP 54

Primary Current ...................................... 16 A

Ambient Temperature ............................ – 20°C to + 60°C (– 4°F bis + 140°F)

Output Voltage ...................................... 8 V - 48 V

Max. Output Current ............................. 110 A