ROTHENBERGER ROWELD ROFUSE Plus V2.0 User Manual
Page 21

ENGLISH
19
7.4
Indication of Power Supply Failure at the Last Welding
The message “Power Supply Failure Last Welding” indicates that the previous welding aborted
because of a power supply failure. The reason may be too weak a generator or too long or too
thin an extension cable, or a tripped cut-out in the mounting box. The next welding operation is
still possible after acknowledging the message by pressing the STOP/RESET key.
8
Configuring the Welding Unit
With the operator identity card, the welding unit can be
reconfigured
Display 8
*** SET-UP MENU ***
Manual Input on
Language -M-
>Date/Time -M-
.
When the MENU key is pressed, the “Enter Menu
Code” message appears on the screen. After the code was read
from the operator card, a screen reading “Settings – M – ” is
displayed, in which the settings menu proper (Display 8) can be
opened by pressing the MENU key again.
In the configuration menu, use the ñ and ò arrow keys to select the desired set-up option. Use
the ð arrow key to toggle between “on” and “off” for that set-up option.
If a “M” is shown next to a set-up option, this indicates that a sub-menu is accessible here by
pressing the MENU key.
Press the START/SET key to confirm the set-up and save it to memory.
Understanding the settings:
“Manual Input on” means that the manual input of welding parameters (see Sect. 6) is possible,
“off,” that the manual input is not allowed (option available only with ROWELD ROFUSE+ V2
model version).
“Language – M – ” means that by pressing the MENU key, the user can access a sub-menu for
selecting the display and report language (see Sect.8.1).
“Date/Time – M – ” means that by pressing the MENU key, the user can access a sub-menu for
setting the clock (see Sect. 8.2).
“Buzzer Volume – M – ” means that by pressing the MENU key, the user can access a sub-menu
for setting the volume of the status buzzer (see Sect. 8.3).
“Temperature Unit – M – ” means that by pressing the MENU key, the user can access a sub-
menu for selecting centigrade or Fahrenheit as the unit for the temperature.
“Inventory Number – M – ” means that by pressing the MENU key, the user can access a sub-
menu for entering the number under which the unit is inventorized with the operating
company.
8.1
Selecting the Display Language
When the “Select Language” sub-menu was selected, the screen
changes and the display reproduced in Display 9 appears
Display 9
***** LANGUAGE *****
>Deutsch
English
Francais
.
Use the arrow keys ñ and ò to select one of the options,
“Deutsch,” “English,” and “Français” and confirmby pressing the
START/SET key.
8.2
Setting the Clock
When the “Set Clock” sub-menu was selected, the screen changes
Display 10
Date/Time
21.06.13 14:28
and the display reproduced in Display 10 appears.
The time of day and the date can be set using the keypad. The
portions “Hour,” “Minute,” “Day,” “Month,” and “Year” are set
separately. Press the START/SET key to confirm your settings.
8.3
Setting the Buzzer Volume
When the “Set Volume” sub-menu was selected, the screen
changes
Display 11
Buzzer Volume
< ------20-------- >
and the display reproduced in Display 11 appears. The
buzzer can also be heard. Turn the buzzer volume up or down to
the desired value using the п, р arrow keys (from 0 to 100) and
confirm your setting by pressing the START/SET key.