beautypg.com

ROTHENBERGER ROWELD ROFUSE Plus V2.0 User Manual

Page 21

background image

ENGLISH

19

7.4

Indication of Power Supply Failure at the Last Welding

The message “Power Supply Failure Last Welding” indicates that the previous welding aborted

because of a power supply failure. The reason may be too weak a generator or too long or too

thin an extension cable, or a tripped cut-out in the mounting box. The next welding operation is

still possible after acknowledging the message by pressing the STOP/RESET key.

8

Configuring the Welding Unit

With the operator identity card, the welding unit can be

reconfigured

Display 8

*** SET-UP MENU ***

Manual Input on

Language -M-

>Date/Time -M-

.

When the MENU key is pressed, the “Enter Menu

Code” message appears on the screen. After the code was read

from the operator card, a screen reading “Settings – M – ” is

displayed, in which the settings menu proper (Display 8) can be

opened by pressing the MENU key again.

In the configuration menu, use the ñ and ò arrow keys to select the desired set-up option. Use

the ð arrow key to toggle between “on” and “off” for that set-up option.
If a “M” is shown next to a set-up option, this indicates that a sub-menu is accessible here by

pressing the MENU key.
Press the START/SET key to confirm the set-up and save it to memory.
Understanding the settings:

“Manual Input on” means that the manual input of welding parameters (see Sect. 6) is possible,

“off,” that the manual input is not allowed (option available only with ROWELD ROFUSE+ V2

model version).

“Language – M – ” means that by pressing the MENU key, the user can access a sub-menu for

selecting the display and report language (see Sect.8.1).

“Date/Time – M – ” means that by pressing the MENU key, the user can access a sub-menu for

setting the clock (see Sect. 8.2).

“Buzzer Volume – M – ” means that by pressing the MENU key, the user can access a sub-menu

for setting the volume of the status buzzer (see Sect. 8.3).

“Temperature Unit – M – ” means that by pressing the MENU key, the user can access a sub-

menu for selecting centigrade or Fahrenheit as the unit for the temperature.

“Inventory Number – M – ” means that by pressing the MENU key, the user can access a sub-

menu for entering the number under which the unit is inventorized with the operating

company.

8.1

Selecting the Display Language

When the “Select Language” sub-menu was selected, the screen

changes and the display reproduced in Display 9 appears

Display 9

***** LANGUAGE *****

>Deutsch

English

Francais

.

Use the arrow keys ñ and ò to select one of the options,

“Deutsch,” “English,” and “Français” and confirmby pressing the

START/SET key.

8.2

Setting the Clock

When the “Set Clock” sub-menu was selected, the screen changes

Display 10

Date/Time

21.06.13 14:28

and the display reproduced in Display 10 appears.
The time of day and the date can be set using the keypad. The

portions “Hour,” “Minute,” “Day,” “Month,” and “Year” are set

separately. Press the START/SET key to confirm your settings.

8.3

Setting the Buzzer Volume

When the “Set Volume” sub-menu was selected, the screen

changes

Display 11

Buzzer Volume

< ------20-------- >

and the display reproduced in Display 11 appears. The

buzzer can also be heard. Turn the buzzer volume up or down to

the desired value using the п, р arrow keys (from 0 to 100) and

confirm your setting by pressing the START/SET key.