Checking the Product for Damage

Before every use of the product, check safety features and possibly existing parts with minor

damage for proper function. Make sure that the push-on connection terminals work properly,

that contact is fully established, and that the contact surfaces are clean. All parts have to be

installed correctly and properly conform to all conditions in order for the product to function as

intended. Damaged safety features or functional parts should be properly repaired or replaced by

an approved service shop.

2.8

General Remark

Comply with the indications and instructions about product maintenance to ensure proper

and safe work. Use only accessories and spare parts that are recommended or approved by the

manufacturer. Using other parts or accessories may put yourself in danger of bodily injury or

cause the device to malfunction.

2.9

Power Supply Specifications

2.9.1 Mains Power Supply

Utility suppliers’ wiring requirements, occupational safety rules, applicable standards, and national

codes have to be respected.

When using power distributions on the worksite, rules for the installation of
earth-leakage circuit breakers (RCD) have to be respected, and operation requires
an installed breaker.

Generator or mains power fuse protection should be 16 A (slow blow). The product has to be

protected against rain and humidity.

2.9.2 Generator Power Supply

The required nominal generator capacity as determined by the power supply requirement of

the largest fitting to be welded depends on the power supply specifications, the environment

conditions, and the generator type itself including its control/regulation characteristics.
Nominal output power for a generator 1 phase, 220 - 240 V, 50/60 Hz:

d 20 .............d 160

3,2 kW

d 160 ............d 450

4 kW mechanically regulated

5 kW electronically regulated

Start the generator first, then connect the welding unit. The idle voltage should be set to approx.

240 volts. When turning the generator off, disconnect the welding unit first.

The working output power of the generator decreases by about 10% per 1,000 m of
altitude. During the welding process no other device connected to the same
generator should be operated.

3

Service and Repair

3.1

General

As the product is used in applications that are sensitive to safety considerations, it may be

serviced and repaired only by the manufacturer or its duly authorized and trained partners. Thus,

constantly high standards of operation quality and safety are maintained.

Failure to comply with this provision will dispense the manufacturer from any

warranty and liability claims for the product, including any consequential damage.

When serviced, the unit is upgraded automatically to the technical specifications of the product at

the moment it is serviced, and we grant a three-month functional warranty on the serviced unit.
We recommend having the product serviced at least every twelve months.
In Germany,we recommend using ROTHENBERGER-Service.

3.2

Transport, Storage, Shipment

The product ships in a transport box. The product should be stored in this box, protects the

product from humidity and environmental agents.
When sending the product, it should be placed into the transport box at all times.