8.4

Selecting the Temperature Unit and Entering the Inventory Number

The unit of temperature values (Centigrade or Fahrenheit) can be selected in a sub-menu similar

to the language selection (see Sect. 8.1). The internal identifier of the welding unit in its owner’s

inventory, a maximum of 8 characters, can be entered using the п, р, с, т arrow keys; it has

then to be confirmed by pressing the START/SET key

9

Self-Monitoring Functions Overview

9.1

Errors During Data Input

Code Error

An erroneous input has occurred, a code tag is poor or has an error in code symbology or code

reading was improper.

No Contact

There is no properly established electric contact between the welding unit and the fitting (check

push-on terminal on fitting), or the heater coil is defective.

Low Voltage

The input voltage is below 175 volts. Adjust generator output voltage.

Overvoltage

The input voltage is over 290 volts. Decrease generator output voltage.

Overheated

The transformer temperature is too hot. Let the welding unit cool down for about 1 hour.

System Error

CAUTION! The welding unit has to be disconnected immediately from both the
power supply and the fitting. The auto-test has detected an error in the system. The
unit must no longer be operated and has to be sent to an approved shop for check
and repair.

Temperature Error

The ambient temperature measured is outside the operating range of the welding unit, i.e., below

– 20°C (– 4°F) or over + 60°C (+ 140°F).

Temperature Sensor Defective

The ambient temperature sensor on the welding cable is damaged or defective.

Clock Error

The internal system clock works improperly or is defective. Reset it, or send the welding unit to

the manufacturer for check and service.

Unit to Service

The recommended next service date for the welding unit is overdue. The service due message has

to be acknowledged by pressing the START/SET key. Send the welding unit to the manufacturer or

an approved service point for service and check-up.

Input Error

A code that was entered is incorrect. At manual welding parameter input, no welding time was

entered. An incorrect value was selected in the date setting.