Tube insert
c.
Note concerning removal of the tubing: Push in collet squarely against face of fitting. With the collet held in this position, the
tube can be removed with a firm pull. Do not attempt to pull the tube out without pushing squarely against the collet. This may
result in damaging the fitting. Further details for using quick-connect fittings are also available here:
http://www.johnguest.com/install_6.shtm#disconnect
d.
Recommended insertion of the MCW40™ in a liquid cooling circuit:
Radiator
CPU
MCW40
Pump
Outlet
Inlet
Inlet
Inlet
Inlet
Outlet
Outlet
Outlet
e.
Re-install the graphics card in the AGP slot, and proceed with filling and bleeding the cooling circuit. A mix of 75% purified
water and 25% antifreeze is recommended
4. Final
inspection
Once the installation is completed, it is always a good idea to test the circuit for leaks, prior to powering up the computer.
Troubleshooting help is available on our web site at
www.swiftnets.com
, or by calling customer support at 562-595-8009.