Swiftech MCR X20 DRIVE REV3 User Manual
One or more patents pending
Copyright Swiftech® 2011
– All rights reserved – Last revision date: 12-13-11 – One or more Patents Pending - Rouchon Industries, Inc., dba Swiftech® –151 West Victoria
St., Long Beach, CA 90805
– Toll free (US) 888-857-9438 – Tel. (310) 763-0336, Fax (310) 763-7095 - E Mail: [email protected] – URL: http://www.swiftech.com -
Information subject to change without notice
– Page 1
INSTALLATION GUIDE
MCR220-DRIVE-B
MCR220-DRIVE
MCR320-DRIVE-B
MCR320-DRIVE
One or more patents pending
MCR DRIVE-B versions (without pump) for existing MCP350 or 355 pump owners
MCP350 or MCP355 pump installation
– skip this step if you have the MCR Drive with integrated pump version
Disassemble the MCP350 or MCP355 pump ports housing from
the main motor housing by loosening and removing all 4 screws.
Reassemble the pump body to the MCR drive radiator while making
absolutely sure to keep the existing pump o-ring in place or the assembly
will leak! To assemble, simply align the pump body with the MCR Drive
pump housing, and fasten it with the supplied 8-
32 x ¾” socket screws.
MCR220 and 320 Drive installation
1. Installation of the fittings :
The MCR Drive heat exchangers are shipped with G1/4 x ½” barb fittings (12mm) . Use a 5/8” (16mm) flat wrench or preferably a socket
wrench to fasten the fittings very tight to the radiator body so as to prevent leaks.
The MCR Drive Rev3 series also feature two additional inlet ports that are available to parallelize various components in installations where
multiple waterblocks are present. See paragraph 5 below for more explanations on the subject matter.