LEVELING AND ANCHORING THE CABINET
1. Place appliance in the installation position.
2.
Place a carpenter’s level on top of the appliance and turn the adjustable feet to level
side-to-side and front-to-back.
3. Mark hole locations on the floor through the anchoring holes provided in the rear
flanged adjustable feet.
4. Remove appliance from installation position and drill holes in locations marked on
the floor. (See installation diagram on page 4.) Insert proper anchoring devices (not
supplied).
5. Place appliance back in the installation position.
6.
Place carpenter’s level on top of appliance and re-level side-to-side and front-to-
back.
7. Bolt and anchor appliance securely to the floor.
8. Seal bolts and flanged feet with silastic or equivalent compound.
ELECTRICAL CONNECTIONS
WARNING: Electrical and grounding connections must comply with the
applicable portions of the National Electrical Code and/or other local
electrical codes.
WARNING: Disconnect electrical power supply and place a tag at the
disconnect switch to indicate you are working on the circuit.
When making electrical connections, use copper wire suitable for at least 200
F (90
C).
The steamer must be grounded in accordance with the National Electrical Code or
applicable local codes. The wiring diagram is located on the inside of the right panel.