Troubleshooting – Blodgett SB-G Series User Manual
Page 23
OM-G-SB 21
Troubleshooting
SYMPTOM
WHO
WHAT TO CHECK
Timer control will not operate.
User
a. Is the electrical supply turned on?
b. Is the ON/OFF switch in the base cabinet turned on?
c. Is boiler started? Is the green light in the ON/OFF switch lit?
d. Are any fuses blown?
No steam to cavities.
User
a. Has steam pressure developed?
b. Is steam supply turned on?
c. Is the door closed? (Doors must be closed before steam will
enter the cavity).
Door leaking steam or water.
User
a. Are the drain holes at the rear of the cavity blocked?
b. Does the door gasket need replacement?
c. Is the door latch in need of adjustment?
(See the Maintenance section).
d. Is the unit level?
Excessive steam coming from
the vent pipe.
User
a. Is the water supply turned on?
b. Is the condenser hose kinked or obstructed?
c. Is the condenser spray solenoid working?
- SG3240G (7 pages)
- MT3255G (2 pages)
- BCX-14G (60 pages)
- B36-RAD (24 pages)
- 1200 (3 pages)
- MT3240E/G (2 pages)
- SN-5G (20 pages)
- SC-7G (20 pages)
- 900 SERIES (22 pages)
- B48N-CCCC (2 pages)
- 1201 (2 pages)
- Conveyor Oven (3 pages)
- 966 (2 pages)
- COMBI B-142G (2 pages)
- AC-500 (15 pages)
- BE2136 (2 pages)
- BC-CCNE (2 pages)
- MT3870 (2 pages)
- KLT-12G (26 pages)
- KLT-12G (2 pages)
- ELECTRIC CONVEYOR OVEN MT1828E (2 pages)
- BG3240 (36 pages)
- R11021 (17 pages)
- RE-42 (2 pages)
- MT3855G (2 pages)
- COMBI COS-20G (2 pages)
- COS (2 pages)
- 1400 SERIES (18 pages)
- COMBI BC142EDS (2 pages)
- BG2136 (2 pages)
- 1415 (2 pages)
- 1415 (13 pages)
- ZEPHAIRE-E PLUS (2 pages)
- SHO-G (2 pages)
- S1820G (50 pages)
- MT2136E/G (2 pages)
- 1405 (2 pages)
- 1200 SERIES (16 pages)
- BCM (24 pages)
- BCT (47 pages)
- BC-20E (30 pages)
- BCP (52 pages)
- BDO-100-E (15 pages)
- DFG-100-ES (26 pages)
- Zephaire-100-G-Es (25 pages)