AT-FS20x and AT-FS202SC/FSx Series Installation Guide
13
3.
Configure the DIP switches. Refer to Figure 3 on page 2 for the location of
the DIP switches and Table 6 for the possible settings.
When setting the DIP switches, consider the following:
❑
Setting the Auto Neg DIP switch for the twisted pair port to ON or
OFF enables or disables auto-negotiation for the port. If you disable
auto-negotiation, be sure to set the DIP switches for the port’s speed
and duplex mode to match the speed and duplex mode of the end-node.
❑
For the fiber optic port, set the port’s duplex mode using the
appropriate Duplex Mode DIP switch. This setting must match the
duplex mode capability of the end-node to be connected to the port.
4.
If you are installing the switch in an AT-MCR12 chassis, refer to the
chassis’ installation guide for instructions on how to install the switch,
then proceed to Step 7.
Table 6 DIP Switch Settings
DIP
Switch
Number
Port
Setting
Position
Description
1
2
Speed (Mbps)
Up
Down
The twisted pair port is operating at 10
Mbps.
The twisted pair port is operating at 100
Mbps.
2
1
Duplex Mode
Up
Down
The fiber optic port is operating at half-
duplex mode.
The fiber optic is operating at full-duplex
mode.
3
2
Duplex Mode
Up
Down
The twisted pair port is operating at half-
duplex mode.
The twisted pair port is operating at full-
duplex mode.
4
2
Auto Neg
Up
Down
Auto-negotiation on the twisted pair port is
OFF.
Auto-negotiation on the twisted pair port is
ON.