23

If this is the last chassis in the stack, you can connect the
stacking cable to either port. For cabling guidelines, see the
next section.

Cabling a Media Converter Stack

To create a stack of media converters, you daisy-chain the units
with the Stack ports. The Stack port on the AT-MCF2000M
Management Module must be connected to the STACK 1 or
STACK 2 port on the AT-MCF2000S Stacking Module in the next
chassis.

Connect the remaining Stack port on the stacking module to the
STACK 1 or STACK 2 port in the next chassis, and so on. Loops
and redundant connections are not supported. For cable
specifications, see “Cable Requirements” on page 15.

To cable a media converter stack, perform the following
procedure:

1.

To connect the AT-MCF2000M Management Module to the
AT-MCF2000S Stacking Module, connect the Stack port on
the management module to either the STACK 1 or STACK 2
port on the stacking module. See Figure 7 on page 24.