beautypg.com

Port status – Axis Communications Axis Video Server AXIS 240Q User Manual

Page 27

background image

27

AXIS 240Q - Event Configuration

6. Adjust the size (drag the bottom right-hand corner) and position (click on the text

at the top and drag to the desired position).

7. Adjust the Object size, History and Sensitivity profile sliders (see table below for

details). Any detected motion within an active window is then indicated by red

peaks in the Activity window (the active window has a red frame).

8. Click Save.

Please use the online help

for descriptions of each available option.

High

Only very large objects
trigger motion detection

An object that appears in the region will
trigger the motion detection for a long
period

Ordinary colored objects against ordinary
backgrounds will trigger the motion
detection

Low

Even very small objects
trigger motion detection

An object that appears in the region will
trigger motion detection for only a very
short period

Only very bright objects against a dark
background will trigger motion detection

Default values Low

Medium to High

Medium to High

Examples:

• Avoid triggering on small objects in the image by selecting a high

size level.

• To trigger motion detection as long as there is activity in the area, select a high

history level.

• To only detect flashing light, low

sensitivity can be selected. In other cases, a high sensitivity level is

recommended.

Port Status

Under Event Configuration > Port Status, there is a list that shows the status for the

connected inputs and outputs of the AXIS 240Q. This is for the benefit of an operator, who

cannot access the System Options section.

Example:

If the Normal state for a push button connected to an input is set to Open circuit, as long as the button is

not pushed, the state is inactive. If the button is pushed, the state of the input changes to active.

If there are parts of the Include window that you wish to exclude, click the
Configure Excluded Windows radio button and repeat steps 1-8 above.

Parameter

Size

History

Sensitivity