beautypg.com

Appendix a specifications, Appendix b troubleshooting – Maximum Summit User Manual

Page 9

background image

8

Appendix A Specifications

Measurement Range and Resolution

Wind speed

0 to 255 MPH

1 MPH

Wind direction

16 compass points

22.5°

Temperature

-40 to 122 °F

1°F

Accuracy

Wind speed

±2.1 MPH

Wind direction

±11.25°

Temperature

0 to 100 °F ±2.0°F

-40 to 122 °F ±2.5°F

Power Requirement

24 to 28 VDC @ < 1Amp

Appendix B Troubleshooting

If you have a problem with Summit, please try the following troubleshooting instructions to narrow
down the source of the problem, before contacting us. If you need further assistance you may contact
us at:
Maximum Inc.
30 Samuel Barnet Blvd.
New Bedford, MA 02745
(508) 995-2200
Fax (800) 989-2580
e-mail - [email protected]
Also check our web site for late breaking information - www.maximum-inc.com

Symptom

Things to check

LED’s do not light.

AC Adapter wiring.
AC adapter power, 24 to 28 VDC.
AC outlet power, 110 to 120VAC.
Indicator fuse.

Fuses keep blowing.

AC Adapter wiring.

No wind speed reading.

Wind speed sensor wiring.
Field Test: Disconnect the wind speed sensor wires
from the terminal connector. Using a jumper wire (a
paper clip will do), momentarily make a short circuit
between terminals #7 and 8, a few times per second.
You should get a reading on the wind speed display. If