Campbell Scientific RF300-Series DRL VHF/UHF Radio Transceivers User Manual
Page 59

J-1
APPENDIX J. CABLE PIN OUTS AND LED FUNCTION
FOR RF95A AND RF300
TABLE J-1. Radio 10 Pin RF Connector
10 Pin
Radio
Radio Description / Usage
1
Not used: TX Wideband (IN)
2
Not used: RX Wideband (OUT)
3
Not used: Frequency Select (IN)
Logic High = Freq. 1, GND = Freq. 2
4
Ground via pin 9
5
12VDC (IN)
6
Push To Talk [PTT] (IN) Logic High
7
Carrier Detect (OUT)
8
TX Data (IN)
9
Ground
10
RX Data (OUT)
TABLE J-2. RF95A 10 Pin RF Connector
10 Pin
Modem
RF Modem Description / Usage
1
RXD (IN)
2
GND
3
Frequency Channel 1 or 2
4
Not used
5
TXD (OUT)
6
TXD Return
7
Not used
8
Sleep Mode
9
Receive/Transmit Control
10
Not used
FYI - All unused pins of the RF
Modem are connected to Ground
on the RF Modem.
TABLE J-3. Radio to RF95A Cable Pin Outs
10 Pin
10 Pin
Extra
Radio
RF Modem
Connections
Description / Usage
1
8
Sleep Mode
2
3
3
Frequency Select (IN) Logic High.
No connection = Freq. 1; GND = Freq. 2
4
6
TX Ground
5
N/C
Red wire
12VDC (IN to Radio)
6
9
PTT Button
Push To Talk [PTT] (IN To Radio From RF Modem)
7
2
Carrier Detect (OUT From Radio To RF Modem)
8
5
TX Data (IN To Radio From RF Modem)
9
2
Black wire
Ground
PTT Button Return
10
1
RX Data (OUT)
- 014A Met One Wind Speed Sensor (36 pages)
- 020C Wind Direction Sensor (26 pages)
- 024A-L Met One Wind Direction Sensor (30 pages)
- 03001-L R.M. Young Wind Sentry Set (34 pages)
- 03002, 03101, and 03301 R. M. Young Wind Sentry Sensors (40 pages)
- 034A-L WindSet (16 pages)
- 034B-L Met One Windset (34 pages)
- 036, 038 Spark Gapped Junction Box (6 pages)
- 05103, 05103-45, 05106, and 05305 R. M. Young Wind Monitors (30 pages)
- 083E Relative Humidity and Temperature Sensor (22 pages)
- 0871LH1 Freezing Rain Sensor (31 pages)
- 092 Barometric Pressure Sensor (24 pages)
- 10164-L Water Sampler Control Cable for use with Isco and Sigma Autosamplers (18 pages)
- 107-L Temperature Probe (28 pages)
- 108-LC Temperature Probe for MetData1 (12 pages)
- 108-L Temperature Probe (30 pages)
- 109-L Temperature Probe (30 pages)
- 109SS Temperature Probe (32 pages)
- 110PV Surface Temperature Probe (32 pages)
- 21108 RF450 Demo Kit (14 pages)
- 223-L Delmhorst Cylindrical Soil Moisture Block (28 pages)
- 227-L Delmhorst Cylindrical Soil Moisture Block (24 pages)
- 229 Water Matric Potential Sensor and CE4/CE8 (34 pages)
- 237-L Leaf Wetness Sensor (14 pages)
- 247-L Conductivity and Temperature (18 pages)
- 253-L and 257-L (Watermark 200) Soil Matric Potential Sensors (36 pages)
- 25458 DIN-Rail Terminal Kit (10 pages)
- 255-100 Novalynx Analog Output Evaporation Gauge (16 pages)
- 260-953 Alter-Type Wind Screen for Tipping Bucket Rain Gages (14 pages)
- 27106T Gill Propeller Anemometer (18 pages)
- 30066 Battery Terminal Bus (1 page)
- 380, 385, 380M, 385M Met One Rain Gages (22 pages)
- 3WHB10K 3-Wire Half-Bridge Terminal Input Module (14 pages)
- 43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield (40 pages)
- 4386 Battery Terminal Bus (1 page)
- 4WFB120, 4WFB350, 4WFB1K 4-Wire Full Bridge Terminal Input Module (22 pages)
- 4WFBS120, 4WFBS350, 4WFBS1K 4 Wire Full Bridge Terminal Input Modules (46 pages)
- 4WPB100, 4WPB1K PRT Terminal Input Modules (16 pages)
- 52202 Electrically Heated Rain and Snow Gage (16 pages)
- 9522B Iridium Satellite Modem and COM9522B Interface Modem (46 pages)
- A100LK Anemometer (18 pages)
- A150 Desiccated Case (12 pages)
- A21REL-12 Relay Driver (10 pages)
- A6REL-12 Relay Driver (12 pages)
- AL200 ALERT2 Encoder, Modulator, and Sensor Interface (44 pages)