2. multi-point network led status – Campbell Scientific ET107 Evapotranspiration Monitoring Station User Manual
Page 80
ET107 Weather Station
TABLE 4-2. Multi-Point Network LED Status
Master
Slave
Repeater
Condition
Carrier
Detect
(CD)
Transmit
(TX)
Clear to
Send
(CTS)
Carrier
Detect
(CD)
Transmit
(TX)
Clear to
Send
(CTS)
Carrier
Detect
(CD)
Transmit
(TX)
Clear to
Send
(CTS)
Powered, not
linked
Solid
bright
red
Solid
dim red
Off
Solid
bright
red
Off
Blinking
red
Solid
bright
red
Off
Blinking
red (a)
Repeater and
Slave linked to
Master, no data
Solid
bright
red
Solid
dim red
Off
Solid
green
Off
Solid
bright
red (a)
Solid
green
Solid
dim red
Solid
bright
red (a)
Repeater and
Slave linked to
Master, Master
sending data to
Slave
Solid
bright
red
Solid
dim red
Off
Solid
green
Off
Solid
bright
red (a)
Solid
green
Solid
dim red
Solid
bright
red (a)
Master
Slave
Repeater
Repeater and
Slave linked to
Master, Slave
sending data to
Master
Solid
bright
red
OR
Solid
green
RCV
data
Solid
dim red
Intermittent
flashing
red
Solid
green
Intermittent
flashing
red
Solid
bright
red (a)
Solid
green
Solid
bright
red
Solid
bright
red (a)
Master with
diagnostics
program
running
Solid
bright
red
Solid
dim red
Intermittent
flashing
red
Solid
green
Intermittent
flashing
red
Solid
bright
red (a)
Solid
green
Solid
bright
red
Solid
bright
red (a)
(a) Clear to Send will be solid red with a solid link, as the link weakens the CTS on the Repeater and Slave will begin to
flash.
If DevConfig is unable to establish a connection with the RF450:
1. Check that LoggerNet/PC400 is closed.
2. Check power to the radio. The Carrier Detect (CD) light should be
flashing red.
3. Check serial cable connections.
4. Check serial port assignment for DevConfig.
5. Press green Setup button on the RF450 and wait several seconds. CD and
Clear to Send (CTS) lights should be solid green.
70