Average(1, SlrRad_W, FP2, 0)
Maximum(1, SlrRad_W, FP2, 0, False)
Maximum (1,DewPntC,FP2,False,False)
Minimum (1,DewPntC,FP2,False,False)
Maximum (1,WindChilC,FP2,False,False)
Minimum (1,WindChilC,FP2,False,False)
Maximum (1,HeatIndxC,FP2,False,False)
Minimum (1,HeatIndxC,FP2,False,False)
EndTable
DataTable (STATS,TRUE,168)
DataInterval (0,60,Min,10)
Totalize (1,one,IEEE4,disable_flag)
FieldNames ("n_TOT")
Totalize (1,one,IEEE4,diag<>1)
FieldNames ("diag_1_TOT")
Totalize (1,one,IEEE4,diag<>2)
FieldNames ("diag_2_TOT")
Totalize (1,one,IEEE4,diag<>4)
FieldNames ("diag_4_TOT")
Totalize (1,one,IEEE4,diag<>8)
FieldNames ("diag_8_TOT")
Totalize (1,one,IEEE4,diag<>9)
FieldNames ("diag_9_TOT")
Totalize (1,one,IEEE4,diag<>10)
FieldNames ("diag_10_TOT")
Totalize (1,one,IEEE4,diag<>NaN)
FieldNames ("no_data_TOT")
EndTable
BeginProg
'Set all rain variables to zero.
For n = 1 To 24
Rain(n) = 0
Next n
one = 1
SerialOpen (Com1,38400,3,0,432)
Scan(5,Sec, 3, 0)
BattVolt = Status.Battery(1,1)
LogrTmpC = Status.PanelTemp(1,1)
WatchDog = Status.WatchdogErrors(1,1)
Overruns = Status.SkippedScan(1,1)
LowVolts = Status.Low12VCount(1,1)
LiBattV = Status.LithiumBattery(1,1)
VoltSe(Encl_RH, 1, mV2500, 10, False, 0, _60Hz, 0.1, 0)
If Encl_RH > 100 Then Encl_RH = 100
SerialInRecord (Com1,in_bytes_str,&h02,0,&h0d0a,nmbr_bytes_rtrnd,01)
WindDir = Mid (in_bytes_str,3,3)
WindSpd_ms = Mid (in_bytes_str,7,6)
diag = Mid (in_bytes_str,16,2)
checksum_flg = ( (HexToDec (Mid (in_bytes_str,20,2))) EQV (CheckSum (in_bytes_str,9,18)))
disable_flag = (NOT (checksum_flg) OR (nmbr_bytes_rtrnd=0) OR (diag<>0))
WindSpd_mph = WindSpd_ms * 2.236936
PulseCount(Rain_mm, 1, 2, 2, 0, 0.254, 0)
RainHrTtl = Rain_mm + RainHrTtl
Rain24Ttl = Rain_mm + Rain24Ttl
If TimeIntoInterval(0,60,Min) Then
Rain24Ttl = 0
For n = 24 To 2 Step -1
Rain(n) = Rain(n-1)
Rain24Ttl = Rain24Ttl + Rain(n)
Next n
RainHrTtl = 0
EndIf
PortSet(9, 1)