Appendix B. PS24 24 Ahr Power Supply and 10 x 12 inch Enclosure

13. Follow the Installation of Battery procedure provided in FIGURE B-10.

Plug the battery into the connector on the CH100 marked “INT”.

FIGURE B-10. Procedure for installing and connecting battery

14. An extra loop of ground wire was sent with the station. Use it to ground

the enclosure to the grounding rod system. The external ground lug is

mounted on the bottom left hand corner of the 10 x 12 enclosure.

15. Flip the switch to “ON”, and test drive the station.

16. After everything checks out, find the gray duct putty that was included in

the enclosure supply kit. Seal the cable-entry conduit by placing putty on

the inside and outside of it. Push the putty down into the cable entries.

B-11