beautypg.com

Specifications – Campbell Scientific HC2S3 Temperature and Relative Humidity Probe User Manual

Page 14

background image

Model HC2S3 Temperature and Relative Humidity Probe

The HC2S3-L's cable can terminate in:

• Pigtails that connect directly to a Campbell Scientific datalogger

(cable termination option –PT; see Section 4).

• Connector that attaches to a prewired enclosure (cable termination

option –PW).

• Connector that attaches to a CWS900 Wireless Sensor Interface (cable

termination option –CWS). The CWS900 enables the probe to be used
in a wireless sensor network.

• Connector that attaches to the Temp/RH connector on a CS110

Electric Field Meter or ET-series weather station (cable termination
option –C).

• Military-style connector that attaches to the Temp/RH connector on a

RAWS-P Permanent Remote Automated Weather Station (cable
termination option –RQ).

The HC2S3-QD is included with the RAWS-F Quick Deployment Remote
Automated Weather Station and can be ordered as a replacement part. Its cable
has a 65-in. length and terminates in a military-style connector that attaches to
the Temp/RH connector on the RAWS-F connector panel.

6. Specifications

Features:

• Well-suited for long-term, unattended applications

• Accurate and rugged

• Compatible with all Campbell Scientific dataloggers (including the

CR200(X) series)

Compatibility: CR200(X)

series

CR800

series

CR1000
CR3000
CR5000
CR9000(X)
CR7X
CR510
CR10(X)
CR23X
21X

Operating Limits at Electronics: -40

° to +100°C

Storage Temperature: -50

° to +100°C

Probe Length:

85 mm (3.3 in.), 183 mm (7.25 in.)

including

connector

Probe Diameter:

15 mm (0.6 in.)

Probe Weight:

10 g (0.35 oz)

Filter:

Polyethylene or Teflon (optional,

ordered

separately)