Installation and maintenance, Sr series inverter, 1. rear panel – Samlex America SR1000-148 User Manual
Page 9: Anel
SR Series Inverter
8
3. Installation and Maintenance
3-1. Rear Panel
R
EAR
P
ANEL
V
IEW
DC INPUT
NEGATIVE(-)
DC INPUT
POSITIVE(+)
ROMOTE
CONTROL
TERMINAL
DRY
CONTACT
TERMINAL
STANDARD
RS-232
FG
AC
OUTPUT
SOCKET
AC
INPUT
SOCKET
AC
INPUT
BREAKER
3-1-1. AC Input Breaker:
The AC input circuit breaker protects the unit from overload. When an overload
condition occurs, the circuit breaker trips and disconnects the AC grid power
input. To reset it, push the circuit breaker button. The cause of tripping should
be ascertained and corrected before the unit is reset .
3-1-2. AC wiring connections:
▌
AC socket:
▌
Connect AC input wiring to the Inverter socket.
Please use the following information as your reference:
FG
FG
L
N
FG
AC INPUT
BREAKER
RL2
RL3
BYPASS RELAY
N
L
INVERTER
"L"
INVERTER
"N"
L
N
L
N
FG
AC output receptacles
for 120VAC version
(NEMA5-15R)
AC Input Receptacle
(IEC 60320 C 14)
AC output sockets for
230VAC output version
(IEC 60320 C 13 receptacles)
or
Max. 60V
INV.
FAILURE
RS-232
AC INPUT
BREAKER
CHASSIS
GROUND
WARNING:
POS(+)
NEG(-)
REVERSE POLARITY
WILL DAMAGE UNIT
AC INPUT
120Vac
10A 47-63Hz
OUTPUT
120Vac
10.3A max.
GND
ENB
ENB
NC
NO
COM.