Data pertaining to the DC input voltage, AC output voltage, AC output
frequency, AC output current, etc. and system status can be shown
sequentially on the LCD display by pressing these buttons. Please refer to
chapter 5 for more information.
3-3-4. FAN ventilation grille (1)~(3): The fans behind the ventilation grilles provides
cooling.
DOT NOT obstruct these vents!
3-4. Maintenance
3-4-1. Make sure that the fan vents are not blocked.
3-4-2. Use a vacuum cleaner to remove any dust from the fan area.
3-4-3. When cleaning the case or front panel, use a soft, dry cloth, only. If the case
or front panel is very dirty, use a neutral, non-abrasive detergent. Do not use
alcohol or ammonia based solutions.
3-4-4. Regular service, and relocation of the inverter, should be performed by a
qualified service technician.
3-4-5. Avoid spilling liquid on the inverter.
4. Operation:
4-1. Connecting the input power
Before making the DC input side connections, the main switch must
be “OFF”.
4-2. Connecting the loads
▌
Calculate the total power consumption(W) of the output load. Make sure that
the total power consumption does not exceed the rated load.
▌
Should the total load exceed the rated capacity of the inverter, remove the
non-critical. loads until the rated total has been reached.
4-3. Inverter Operation
▌
Set the power switch to the “ON” position. The buzzer will sound “beep beep”.
The inverter will carry out self-diagnosis and, the LED’s will also appear various
colors. At the, same time the LCD will display ”SR-1000
INVERTER INITIALIATION..”.
Finally, the buzzer will sound another “beep” and the “INVERTER” and