SR Series Inverter

26

6-1-3. The RS232 interface of this unit employs ASCII code to implement the

asynchronous serial transmission control.

The byte structure is START-BIP – 8 BIT DATA-STOP BIT.

Baud rate: 1200/2400/4800/9600(See details in Section 5-3-1).

6-1-4. Coupled with PC software application port. Operation is as detailed in

Section 6-2.

6-2. Interface Commands:

The buffer size used for the RS232 port is 12-byte. This unit will ignore all bytes

more than this value. During transmission, this unit will indicate it is ready to

receive data from computer by this DTR line. A computer has to check the DTR

line before sending any information to this unit. This unit is normally always

ready to receive data while operating. When a LF character (ASCII code 0AH)

is received, this unit would finish the receiving by clearing the DTR status and

begin to interpret the received information. The unit would execute the received

command (AND/OR data) if it is correct. Irrespective of whether the command is

accepted or not, the unit will always send back a response signal to the

computer and set DTR to ready for receiving more incoming information.

6-2-1. The Baud-rate of the RS232 interface can be set with the help of the Setup

Menu (See details in Section 5-3-1).

Note. You have to reset the unit after adjustment to activate the new setting.

6-3. Example of the RS232 Operation:

6-3-1. RS232 command:

Command format:

This unit uses high-level language commands with a CR (0DH) and

LF (0AH) as the end of the command.

The system would interpret and execute the command only after these two

characters are received. After the unit execute the command, it would send

a response string to the computer. The response string is as follows:

= > CR LF: Command executed successfully

? > CR LF: Command error, not accepted

! > CR LF: Command correct but execution error (e.g. parameters out of

range).

If the command needs any information from the unit, the unit would send

the information back to the computer (with CR and LF) and then send the

response string to the computer.