Possible cause, No ac power “output, Information – Samlex America SR1000-148 User Manual
Page 32: Appendices, Sr series inverter
SR Series Inverter
31
7. Information
7-1. Troubleshooting
Problems and Symptoms
Possible Cause
Solutions
No AC Power “Output”
a. LCD Panel Display
“OLP Shutdown”
Short circuit , wiring
error. over loading.
Check AC wiring for
short circuit .
Reduce load.
b. LCD Panel Display
“OVP Shutdown”
Over input voltage
(OVP)
Check input voltage
Reduce input voltage
c. LCD Panel Display
“UVP Shutdown”
Low input voltage.
(UVP)
Recharge battery.
Check connections
and cables.
d. LCD Panel Display
“OTP shutdown”
Thermal shutdown.
(OTP)
Improve ventilation.
Make sure ventilation,
grilles / slots of the
inverter are not
obstructed. Lower
ambient temperature.