Appendix A. Format List

39


Fmt 72:

[transit] [acct #]


[transit]:

- all characters in the field

-

remove

dashes


[acct #]:

- maximum of N characters (N is on quick-init check)

- remove spaces and dashes


Fmt 73:

[transit] [acct #] [check #]


[transit]:

- all characters in the field

-

remove

dashes


[acct #]:

- maximum of N characters (N is on quick-init check)

- remove spaces and dashes


[check #]:

- all characters in the field

- remove dashes and spaces


Fmt 74:

[transit] [acct #] [check #]


[transit]:

- all characters in the field

-

remove

dashes


[acct #]:

- always N characters (N is on quick-init check), zero filled

- remove spaces and dashes


[check #]:

- always 8 characters, zero filled

- remove spaces and dashes