Micrparsests1, Able – MagTek Excella STX99875340 User Manual
Page 90

Excella Windows API Specifications
80
MICRParseSts1
This key specifies a 2-digit status/error code reported by the device after parsing the MICR fields read
from the check. This key is supported by Excella and Excella STX.
Values
Value Description
numeric value
For specific status/error code information refer to table 6-10
Table 6-10. MICRPARSESTS1
PRIORITY MICRParseSts1
TYPE
DESCRIPTION
10
01
Error
No MICR data: no transit and no account found
9
09
Status
Mexican check
8
08
Status
Canadian check
7
05
Error
No transit, bad character, bad length, bad check digit
6
07
Error
No account, bad character
5
04
Error
Bad character in check number
5
04
Status
No check number
4
12
Status
Short Account (maybe caused by mis-parsed check#)
3
03
Status
Low MICR signal, good read
2
10
Status
Business check
1
11
Status
Amount field present
0
00
Status
No error, check OK
Notes:
•
The LED indicator will turn red on all error conditions.
•
The absence of a check number is not considered an error.
•
If a multiple error occurs, the error or status code with the highest priority is reported.
•
All unreadable MICR characters are transmitted as an “?” ASCII character (hex 3F), except for Format 00xx.