Accessguide, Expressenabled, Usbspeed – MagTek Excella STX99875340 User Manual
Page 105: Starttimeout

Section 7. Other Keys Available from Device
95
AccessGuide
This key specifies the status of the top cover on the Excella STX device or the status of the access guide
on the Excella device. This key is supported by Excella and Excella STX.
Values
Value Description
UNKNOWN
Status is undetermined
LATCHED
The top cover is latched and installed
UNLATCHED
The top cover is unlatched or removed
ExpressEnabled
This key specifies if Excella is set as “express mode”. This key is supported by Excella only.
Values
Value Description
TRUE
The device is set as express mode
FALSE
The device is set as normal mode*
*
If the USB speed is USB1.1, the device is ALWAYS set as normal mode. This value is ALWAYS set as
“FALSE”.
USBSpeed
This key specifies the protocol of USB connection. This key is supported by Excella only.
Values
Value Description
HI
The current USB connection is USB2.0
LOW
The current USB connection is USB1.1
StartTimeout
This key specifies the firmware Timeout on check entry. This key is supported by Excella and Excella
STX.
Values
Value Description
numeric value
Time, in milliseconds