Section 6. Keys Received From Device
77
MICRChkType
This key specifies the check type based on the presence on the Auxiliary On-Us MICR field. This key is
supported by Excella and Excella STX.
Values
Value Description
PERSONAL
Auxiliary On-Us MICR field NOT present
BUSINESS
Auxiliary On-Us MICR field present
MICRCountry
This key specifies the country of origin based on known MICR line formats. This key is supported by
Excella and Excella STX.
Values
Value Description
USA
Check drawn in USA
CANADIAN
Check drawn in Canada
MEXICAN
Check drawn in Mexico
MICRDecode
This key indicates whether a MICR decode/read error was detected. This key is supported by Excella and
Excella STX.
Values
Value Description
NONE
No MICR data detected
OK
MICR decode/read was successful
ERROR
Error detected in MICR decode/read operation
MICREPC
This key specifies the EPC MICR field read from the check. This key is supported by Excella and Excella
STX.
Values
Value Description
string
EPC MICR field
MICROnUs
This key specifies the On-Us MICR field read from the check. This key is supported by Excella and
Excella STX.
Values
Value Description
string
On-Us MICR field