Excella Windows API Specifications
112
Fmt 3300:
'=' [transit] '=' [acct #] '=' [check #] '=' [status]
• [transit]:
- all characters in the field
- remove dashes
• [acct #] :
- maximum of 14 digits
- remove spaces and dashes
• [check #]:
- maximum of 8 digits
- remove spaces and dashes
• [status]:
- this is a programmable option that must be enabled (See Table 2-4).
Fmt 34xx:
[transit] [acct #] [zero fill]
• [transit]:
- all characters in the field
- remove dashes
• [acct #]:
- all characters in the field
- remove spaces and dashes
• [zero fill]: - zero filled up to xx; xx must be greater than 00
Fmt 3500:
MA [aux] B [epc] C [tran] D [acct] E [chk] F [tpc] G [amt]
This format is defined specifically for Target Test Checks. A description of the
Target Test Check must be loaded in the exception table.
• [aux], [epc], [tran], [chk], [tpc], [amt]:
- all characters in the field
- keep spaces and dashes
• [acct]:
- all characters in the field
- keep spaces and remove dashes
Fmt 36xx:
Read OK : [transit] [acct #] [check #] '/'
Read error: '0' '/'
• [transit]:
- all characters in the field
- remove spaces and dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent
- remove spaces and dashes
• [check #]:
- always 6 characters, zero filled
- remove spaces and dashes