Scanonce, Section = endorser, Printdata – MagTek Excella STX99875340 User Manual
Page 68: Printfrontdata

Excella Windows API Specifications
58
Values
Value Description
SEQ_9
If there is check found in the check path, the check moves in the reverse
direction towards the entry point, and the check leaves the unit. Motor is
always turned on to ensure the path is completely clear. No scanning, printing
or MICR reading operations are performed during this sequence.
Invalid Conditions:
This operation will not take place if there is no check found in the check
path.
A check that is pinched at the exit point (after check processing is
completed) is considered to be out of the path.
SEQ_10
If there is check found in the check path, the check moves to a point near the
back printer. No scanning, printing or MICR reading operations are performed
during this sequence.
ScanOnce
This setting is only for MagUSB express mode.
If this setting is YES, the unit will automatically scan the next check.
If this setting is NO, the unit will scan only one check whether or not there are any other checks in the
auto feed tray.
Values
Value Description
YES
If ExpressEnabled is TRUE, the unit will automatically scan the next check.
NO
If ExpressEnabled is TRUE, the unit will scan only one check regardless of the
number of checks in the auto feed tray.
SECTION = Endorser
The Endorser section includes keys that control various options for printing on the check.
PrintData
This key specifies the text to be printed on the back of the check (i.e., endorsement message). This key is
supported by Excella and Excella STX.
Values
Value Description
string
Specifies text for the endorsement message
PrintFrontData
This key specifies the text to be printed on the front of the check (i.e., franking message). This key is
supported by Excella and Excella STX.
Values
Value Description
string
Specifies text for the franking message