3 electrical, 4 communications, 5 protocols – Videotec ULISSE NETCAM User Manual
Page 46: 6 environment, 7 certifications

EN - English - I
nstruc
tions manual
44
15.3 Electrical
Suitable for use with network cameras
Input voltage:
- 230Vac, 50/60Hz, 100W
- 24Vac, 50/60Hz, 100W (150-190W max, with LED
illuminators)
- 120Vac, 50/60Hz, 100W
Current consumption:
- 230Vac, 0.4A
- 24Vac, 4A (8A, with LED illuminators)
- 120Vac, 0.8A
Camera power supply: 12Vdc (800mA)
4 self-powered alarm inputs
2 clean contacts: 30Vdc max or30Vac, @ 1A
15.4 Communications
Ethernet connection: IEEE 802.3 100Base-Tx
15.5 Protocols
ONVIF, S profil
15.6 Environment
Indoor/Outdoor
Operating temperature (with heater): -20°C
(-4°F)/+60°C (140°F)
Operating temperature (with reinforced heater):
-30°C/+60°C (140°F)
Wind resistance (without LED illuminators):
- Operational: up to 160km/h
- Stationary: up to 210km/h
Resistant to salty fog (EN50130-5, EN60068-2-52)
Surge immunity: up to 2KV line to line, up to 4KV line
to earth (Class 4)
15.7 Certifications
CE: EN60950-1, EN60950-22, EN61000-6-4, EN55022
Class A, EN50130-4
IP66 EN60529
cULus Listed (not for thermal cameras version)