beautypg.com

HighPoint RocketRAID 4310 User Manual

Page 37

background image

RocketRAID BIOS Utility

To add a disk, install the hard disk, then highlight Disk from the toolbar, select

Rescan, and press Enter.

Note: After installing the disk into the hot-swap capable drive bay, wait several

seconds to allow the disk to fully power on, before using the Rescan command.

Adding/removing Arrays

To prepare a RAID array for removal, highlight the target array using the Array

window and press Enter. Highlight Array from the toolbar, select Unplug, and press

Enter.

The interface will notify you when the disk can be removed.

To add an array, install all of the RAID hard disks, then highlight Window from the

toolbar. Select Refresh, and press Enter.

Note: After installing the hard disks into the hot-swap capable drive bays, wait

several seconds to allow the disks to fully power on, before using the Rescan

command.

37

This manual is related to the following products: